BOSCH FMC-120-DKM-G-Y Manual call point indoor, yellow-Conterway Technology (Shenzhen) Co., Ltd|Huawei|AXIS|Bosch|SONY|Panasonic|Samsung|Honeywell|Theia|Hikvision|Huawei|Senstar Aimetis Symphony™ 365租售宝下载_365英超_365best官网

<legend id="h4sia"></legend><samp id="h4sia"></samp>
<sup id="h4sia"></sup>
<mark id="h4sia"><del id="h4sia"></del></mark>

<p id="h4sia"><td id="h4sia"></td></p><track id="h4sia"></track>

<delect id="h4sia"></delect>
  • <input id="h4sia"><address id="h4sia"></address>

    <menuitem id="h4sia"></menuitem>

    1. <blockquote id="h4sia"><rt id="h4sia"></rt></blockquote>
      <wbr id="h4sia">
    2. <meter id="h4sia"></meter>

      <th id="h4sia"><center id="h4sia"><delect id="h4sia"></delect></center></th>
    3. <dl id="h4sia"></dl>
    4. <rp id="h4sia"><option id="h4sia"></option></rp>

        Product   
        Contact Us   
        Your Position: Home > Product > BOSCH > Burglar Alarm System

        BOSCH FMC-120-DKM-G-Y Manual call point indoor, yellow

        Update: 2020/4/14      View:
        • Brand:    BOSCH
        • Type:    FMC-120-DKM-G-Y
        • Order Online
        Introduction
        BOSCH FMC-120-DKM-G-Y Manual call point indoor, yellow
        Commercial Product No.: FMC-120-DKM-G-Y | Product No.: F.01U.011.955
         
        Adjustment of the manual call point after alarm triggering
        Indicator LED for alarm or for inspection evaluation
        Second contact with connections for panel control
        Variants for indoor and outdoor use
        Select variant
        current tab: Technical Specification
        Parts Included
        Downloads
        Key Specifications
         Full specifications
        Color Yellow, RAL 1003
        Degree of protection (IEC 60529) Form G (indoor area) IP 52
        Operating temperature Form G -10 to 55 °C / 14 °F to 131 °F


        Region Regulatory compliance/quality marks
        Europe Ex 01 ATEX 2163 X OTC/OC 310/410,
        OT/O/T 300/400, DKM/SKM 120, DM/
        SM 210, MPA_01 ATEX 2163 X
        Ex 01 ATEX 2163 X FMC-120-DKM
        Germany VdS G 298061 FMC-120-DKM-G-R/-HR_G29806
        VdS G 206079 FMC-120-DKM-GY_G206079
        VdS G 206080 FMC-120-EST-G-B/-HHE_G206080
        Europe CE FMC-120-EST-G-B / -DKM-G-Y
        CE FMC-120-DKM-G-R/-H-R
        CE FMC-120-DKM-G-B/ -H-B
        CPD 0786-CPD-20294 FMC-120-DKM-G/HR
        CPD 0786-CPD-20231 FMC-120-DKM-G-Y
        CPD 0786-CPD-20232 FMC-120-EST-G-B/-
        H-HE


        Installation/configuration notes
        • Manual call points have to be mounted visibly alongescape and rescue routes (e.g. exits, passageways,
        stairwells) and be easily accessible.
        • An installation height of 1400 mm ±200 mm,measured from the middle of the manual call point to the floor, must be maintained.
        • Manual call points must be illuminated sufficiently with daylight or another light source (including emergency lighting, if present).
        • Max. one test detector may be used for primary lines together with automatic detectors. The test detector
        is connected at the end of the primary line.
        • Further standards, guidelines and planning recommendations regarding the installation location
        etc., should also be taken into consideration (see Fire Detection manual).
        • Regulations of local fire departments must be observed.
        Installation
        • Cables can be inserted surface-mounted or flushmounted.Pos. Description
        1 Installation depth version 1: 36 mm
        2 Installation depth version 2: 14 mm
        3 Installation depth version 3: approx. 30 mm
        Technical specifications
        Electrical
        Operating voltage 24 V DC (16.2 V DC . . .30 V DC)
        Current consumption Specified by the respective security system
        Mechanics
        Dimensions (W x H x D) 135 x 135 x 37 mm / 5.31 x 5.31 x 1.4 in.
        Housing material Plastic (ASA)
        Colors Red, RAL 3001
        Blue, RAL 5005
        Yellow, RAL 1003
        Weight Approx. 224 g
        Environmental conditions
        Protection class as per
        EN 60529
        Form G (indoor area) IP 52
        Form H (outdoor area) IP 54
        Norm
        FMC-120-DKM-G-R,
        FMC‑120‑DKM‑H‑R
        EN 54-11
        FMC-120-DKM-G-Y,
        FMC‑120‑EST‑G‑B
        EN 12094-3
        Permissible operating
        temperature
        Form G (indoor area) -10 °C . . . +55 °C /
        14 °F … 131 °F
        Form H (outdoor area) -25 °C . . . +70 °C /
        -13 °F … 158 °F
        Ordering information
        FMC-120-DKM-G-B Manual call point indoor, blue
        Manual Call Point for indoor use, indirect triggering
        (type B), conventional technology
        Order number FMC-120-DKM-G-B
        FMC-120-DKM-G-R Manual call point indoor, red
        Manual Call Point for indoor use, indirect alarm
        triggering (type B), conventional technology
        Order number FMC-120-DKM-G-R


        FMC-120-DKM-G-Y Manual call point indoor, yellow
        Manual Call Point for indoor use, indirect triggering
        (type B), conventional technology
        Order number FMC-120-DKM-G-Y
        FMC-120-DKM-H-B Manual call point outdoor, blue
        Manual Call Point for outdoor use, indirect triggering
        (type B), conventional technology
        Order number FMC-120-DKM-H-B
        FMC-120-DKM-H-R Manual call point outdoor, red
        Manual Call Point for outdoor use, indirect alarm
        triggering (type B), conventional technology
        Order number FMC-120-DKM-H-R
        FMC-120-EST-G-B Manual stop device, indoor, blue
        Electronic Stop Device for indoor use, indirect
        triggering (type B), conventional technology
        Order number FMC-120-EST-G-B
        Accessories
        FMC-FST-DE Foil set, transparent
        For yellow and blue manual call points of the series
        FMC-120 and FMC-210, 1 unit = 5 sheets
        Order number FMC-FST-DE
        FMC-SPGL-DEIL Spare glass
        For manual call points of series DM, DKM, SKM,
        FMC-120 and FMC-210, 1 unit = 5 spare glasses
        Order number FMC-SPGL-DEIL
        FMM-KEY-FORM G/H Key for manual call point
        made of red plastic (ASA)
        Order number FMM-KEY-FORM G/H