BOSCH FMC-210-DM-G-Y Manual call point indoor, yellow-Conterway Technology (Shenzhen) Co., Ltd|Huawei|AXIS|Bosch|SONY|Panasonic|Samsung|Honeywell|Theia|Hikvision|Huawei|Senstar Aimetis Symphony™ 365租售宝下载_365英超_365best官网

<legend id="h4sia"></legend><samp id="h4sia"></samp>
<sup id="h4sia"></sup>
<mark id="h4sia"><del id="h4sia"></del></mark>

<p id="h4sia"><td id="h4sia"></td></p><track id="h4sia"></track>

<delect id="h4sia"></delect>
  • <input id="h4sia"><address id="h4sia"></address>

    <menuitem id="h4sia"></menuitem>

    1. <blockquote id="h4sia"><rt id="h4sia"></rt></blockquote>
      <wbr id="h4sia">
    2. <meter id="h4sia"></meter>

      <th id="h4sia"><center id="h4sia"><delect id="h4sia"></delect></center></th>
    3. <dl id="h4sia"></dl>
    4. <rp id="h4sia"><option id="h4sia"></option></rp>

        Product   
        Contact Us   
        Your Position: Home > Product > BOSCH > Burglar Alarm System

        BOSCH FMC-210-DM-G-Y Manual call point indoor, yellow

        Update: 2020/4/15      View:
        • Brand:    BOSCH
        • Type:    FMC-210-DM-G-Y
        • Order Online
        Introduction
        BOSCH FMC-210-DM-G-Y Manual call point indoor, yellow
        Commercial Product No.: FMC-210-DM-G-Y | Product No.: F.01U.011.961
         
        Adjustment after alarm triggering
        Individual identification thanks to automatic or manual detector addressing
        Indicator LED for alarm or for inspection evaluation
        Query routines with evaluation and multiple transmission
        Maintains LSN loop functions in the event of wire interruption or short-circuit thanks to two integrated isolators
        show less
        Select variant
        current tab: Technical Specification
        Parts Included
        Downloads
        Key Specifications
         Full specifications
        Operating voltage (VDC) 24 (15 to 33)
        Current consumption (mA) 0.4
        Dimensions W x H x D (mm) 135 x 135 x 40
        Housing material Plastic ASA
        Colors Red RAL 3001 Blue RAL 5005 Yellow RAL 1003 Green close to RAL 6002
        Weight (g) Approx. 235
        Degree of protection (IEC 60529) Form H IP 54
        Degree of protection (IEC 60529) Form G IP 52
        FMC‑210‑DM‑G‑R EN 54-11
        FMC‑210‑DM‑H‑R EN 54-11
        FMC‑210‑DM‑G‑Y EN 12094-3
        Operating temperature Form H (°C) -25 to 70
        Operating temperature Form G (°C) -10 to 55
        The FMC-210-DM Double-action Call Points are used for manual triggering, and can be used in the Local SecurityNetwork LSN and LSN improved. Form H Manual Call Points are designed for outdoor deployment, form G Manual Call Points are designed for indoor deployment.
        In the event of an alarm, the glass pane (2) is broken first, then the manual call point (3) is pressed hard. This activates the microswitch for alarm triggering and the indicator LED (4) blinks. A mechanism holds the pressed call point down. The manual call point can be reset with the reset lever (5) or by closing the door of the manual call point (1). The indicator LED (4) goes out.
        This does not reset the alarm on the fire panel.Individual call point identification with display of the
        call point address on the fire panel ensures the quick location of the triggered call point.
        Variants
        The designs of the manual call points for outdoor and indoor use are identical. The manual call points for
        indoor use (form G) are available in red, blue, yellow,and green. The manual call points for outdoor use
        (form H) are available in red and blue.Form H manual call points are equipped with an especially resistant PC board layered with parylene.
        Notice
        The key must be ordered separately.
        Improved LSN features
        The manual call points offer all the features of the improved LSN technology:
        • Flexible network structures, including T-tapping without additional elements
        • Up to 254 LSN improved elements per loop or stub line
        • Automatic or manual detector addressing selectable via rotary switch, in each case with or without autodetection
        • Shielded and unshielded cables can be used
        • Cable length up to 3000 m (with LSN 1500 A module)
        • Downwards compatibility to existing LSN systems
        and control panels
        Certifications and approvals
        Type Number Complies with
        FMC‑210‑DM‑G‑R : EN 54-11:2001/A1:2005, EN 54-17:2005
        FMC‑210‑DM‑H‑R : EN 54-11:2001/A1:2005, EN 54-17:2005
        FMC‑210‑DM‑G‑Y : EN 12094-3:2003, EN 54-17:2005
        Region Regulatory compliance/quality marks
        Germany VdS G 206098 FMC-210_DM-G-R/-HR_G206098 VdS G 206099 FMC-210_DM-G-Y_G206099
        Europe CE FMC-210-DM-G-B/-H-B/-SM-G-B CE FMC-210_DM-G-R/-H-R/-SM-G-R CE FMC-210-DM-G-Y / EST-G-B CPD 0786-CPD-20293 FMC-210-DM-G/H-R CPD 0786-CPD-20244 FMC-210-DM-G-Y 
        Poland CNBOP 1505/2013 FMC-210 DM-G-R, FMC-210 DM-H-R
        Ukraine MOE UA1.016.0070338-11 FMC-210-DMG-R_FMC-210-DM-H-R_FMC-210-DM-GR-A
        Slovakia EVPÚ SK08-ZSV-0071 FMC-210-DM,FMC-210-EST
        Installation/configuration notes
        • The device must be mounted visibly along escape and rescue routes (e.g. exits, passageways, stairwells) and be easily accessible.
        • An installation height of 1400 mm ±200 mm,measured from the middle of the device to the floor,must be maintained.
        • The device must be adequately illuminated by sunlight or another light source (including emergency 
        lighting if present).
        • The maximum number of LSN elements that may be connected depends on their current consumption from the LSN data line. The limit values should be taken from the product information supplied with the fire panel used.
        • Additional norms, guidelines, and planning recommendations with respect to installation location, etc. must be taken into account (see fire detector manual).
        • The regulations of the local fire services must be observed.
        Technical specifications
        Electrical
        Operating voltage (VDC) 24 (15 to 33)
        Current consumption (mA) 0.26
        Mechanics
        Dimensions W x H x D (mm) 135 x 135 x 40
        Housing material Plastic ASA
        Colors Red RAL 3001
        Blue RAL 5005
        Yellow RAL 1003
        Green close to RAL 6002
        Weight (g) Approx. 235
        Environmental
        Degree of protection (IEC
        60529) Form H IP 54
        Degree of protection (IEC
        60529) Form G IP 52
        FMC‑210‑DM‑G‑R EN 54-11
        FMC‑210‑DM‑H‑R EN 54-11
        FMC‑210‑DM‑G‑Y EN 12094-3
        Operating temperature Form H (°C) -25 to 70
        Operating temperature: Form G (°C) -10 to 55
        Ordering information
        FMC-210-DM-G-B Manual call point indoor, blue 
        Analog addressable manual call point with glass pane for indoor use, indirect alarm triggering (type B), blue 
        Order number FMC-210-DM-G-B
        FMC-210-DM-G-GR Manual call point indoor, green 
        Analog addressable manual call point with glass pane
        for indoor use, indirect alarm triggering (type B), green
        Order number FMC-210-DM-G-GR
        FMC-210-DM-G-R Manual call point indoor, red 
        Analog addressable manual call point with glass pane
        for indoor use, indirect alarm triggering (type B), red
        Order number FMC-210-DM-G-R
        FMC-210-DM-G-Y Manual call point indoor, yellow
        Analog addressable manual call point with glass pane
        for indoor use, indirect alarm triggering (type B),yellow
        Order number FMC-210-DM-G-Y
        FMC-210-DM-H-B Manual call point outdoor, blue
        Analog addressable manual call point with glass pane
        for outdoor use, indirect alarm triggering (type B),blue
        Order number FMC-210-DM-H-B
        FMC-210-DM-H-R Manual call point outdoor, red
        Analog addressable manual call point with glass pane
        for outdoor use, indirect alarm triggering (type B), red
        Order number FMC-210-DM-H-R
        Accessories
        FMX-FSO-LSN FMX-FSO-LSN foilset operating panel MCP
        For the labeling field of manual call points of the series
        FMC-210, 1 unit = 10 sheets
        Order number FMX-FSO-LSN
        FMC-FST-DE Foil set, transparent
        For yellow and blue manual call points of the series
        FMC-120 and FMC-210, 1 unit = 5 sheets
        Order number FMC-FST-DE
        FMC-SPGL-DEIL Spare glass
        For manual call points of series DM, DKM, SKM,
        FMC-120 and FMC-210, 1 unit = 5 spare glasses
        Order number FMC-SPGL-DEIL
        FMM-KEY-FORM G/H Key for manual call point
        made of red plastic (ASA)
        Order number FMM-KEY-FORM G/H
        More Products